ITA 9.1.1 and newer supports installation on RHEL 8. Installing ITA 9.1.0 on a Red Hat operating system is not supported. |
IMPORTANT: To install ITA 9.1.x on VMware, plan to use VMware ESXi 6.5 U1 or newer. Otherwise, you may see a kernel bug error in CentOS 8.x. See VMware KB article https://kb.vmware.com/s/article/2151480 for more information. |
These system specifications are recommendations for your IT Advisor system configuration in general. The performance and operation of the system depends largely on the nature of the configuration, such as:
- Number and population of racks
- Number and nature of integrations to external systems
- Number of devices and number of data points stored on these
- Power path configuration (one big, several small, across rooms, etc.)
- Concurrent and total users of the system and nature of their work cycle
If ITA is running on lower specification servers than recommended, users may experience long response times or timeout issues. In addition, the server may not be able to process scheduled jobs in a timely manner.
Recommended server hardware for IT Advisor on-premises
ITA on-premises requires a dedicated server, either hardware or a virtual environment. The operating system is included in the installation.
Recommended IT Advisor server configuration
Server requirement guidelines (minimum)
- CPU: 4 cores minimum. We recommend 8 cores
- Memory: 16 GB RAM (absolute minimum requirement)
- 100 GB storage, speed minimum 170 MB/s
- Disaster recovery network: 10 Mbps with low latency <100 ms
Note: If you're installing ITA on-premises on an existing server, note that ITA claims almost all memory (JVM about 8 GB and Postgres about 6 GB alone). You might experience issues if you have other applications running on the server, such as surveillance and monitoring agents.
Server requirement guidelines for 10,000 racks across 200 rooms with 30 concurrent users
- 8 CPU cores
- 32 GB RAM
- 100 GB storage, speed minimum 170 MB/s
Server requirement guidelines for 20,000 racks across 400 rooms with 30 concurrent users
- 16 CPU cores
- 64 GB RAM
- 100 GB storage, speed minimum 170 MB/s
RAID systems
Hardware RAID controllers are recommended. We tested hardware controllers in the DELL x20 series, IBM M4 series, and HP G8 series. Be aware there might be hardware RAID controllers that we have not tested in special configurations.
Not supported:
- Generally all software RAID controllers
- HP RAID Controller B-Series
- DELL RAID Controller S-Series
Security configuration
For information about security configuration, see here.
IT Advisor server communication
For information on server communication, see here.
Recommended IT Advisor client configuration
- Processor: 2 GHz Intel Core 2 Duo (or equivalent)
- Hard disk: 500 MB free hard disk space for installation
- Memory: 4 GB RAM
- Display: Absolute minimum 1024x768 screen resolution with 16 million colors, 1280x1024 is recommended. For 3D view to work, 3D hardware including working drivers are needed
- Operating System:
- Windows 10
- OS X latest version
- The latest version of the Java Runtime Environment is needed for the desktop client
- The web client is available on a computer, tablet, or mobile device with an internet browser: Browser: The latest version of Microsoft Edge, Chrome, Safari, or Firefox
- Bandwidth requirement guidelines web client/Tenant Portal:
-
First time loading: 5 MB (this will be cached)
-
Loading a small room: 20 KB
-
Loading a room with 150 racks: 90 KB
- Loading large room (1000 racks): 1.7 MB
-
These are the absolute minimum recommendations for running ITA, For larger setups, better specifications are recommended.