It is recommended that you upgrade to 1.6.2.14 to mitigate potential security vulnerabilities. |
Is your Gateway software older than 1.4.0? Download and install version 1.5.2 before you update to the latest version.
If your Gateway software is older than version 1.4.0, the installer will direct you to download and install Gateway version 1.5.2. Once you log in, you'll see a message that an update is available. You can then update your Gateway to the latest version.
If your Gateway version is 1.4.0 or newer, you can update to the latest version directly.
Log in to your EcoStruxure IT account. Go to Administration > Gateways. Click Update on the gateway tile.
![]() |
You can enable automatic Gateway software updates in EcoStruxure IT. More |
EcoStruxure IT Gateway 1.6.2.14
This release improves the security of the Windows and Linux installers.
Checksum
SHA1
Linux: 5aa4a13737a4c7ac7641495b2818f84e66a5f16a
Windows: ca0c04c70effd85b9823593eeadcfb05998e13f6
EcoStruxure IT Gateway 1.6.1.9
Software updates are now successful on systems with very long APC Network Management Card config.ini text fields.
Checksum
SHA1
Linux: c1f452939674f97d2ae31f8d82609fbd003b8259
Windows: 2f7a838ac3a76a77b996f5741127b365c523cf30
EcoStruxure IT Gateway 1.6.0.39
Installer
The EcoStruxure IT Gateway 1.6.0.39 installer was updated to meet the latest security requirements.
Security enhancements
- If you have run a Gateway backup and stored it in a vulnerable location, data in the backup file may be at risk of being compromised. For the utmost security, it is recommended that you change these credentials after updating to the 1.6.0.39 release:
- Gateway user accounts
- Discovered devices
- Backup locations
- You must now supply a password for the Gateway (zipPw) to restore from backup. This is the serial number of the Gateway. How to find the Gateway serial number
- Database security was improved.
- Possible cross site scripting exploits were addressed.
Device support
Added support for:
- Liebert EPMP
- Liebert cooling PCW/PDX
- APC Power Management Module
Issues fixed
- UPS Battery Age is now displayed as expected.
- Galaxy VS Bypass Switch sensor is now supported.
- PPC UPS sensors and attributes
System updates
- Updated TomCat to version 8.5
- Replaced the Oracle JRE with Amazon Open JDK
Browser support
- EcoStruxure IT no longer supports Microsoft Internet Explorer. Use Microsoft Edge, Firefox, Chrome, or Safari.
Checksum
SHA1
Linux: 29a6be32763361c8469b0df7e39b15be378137dc
Windows: 6ed63edd6d5d00a7dcdf196b5950260806934abd