See the most recent device library release notes in the new help center. |
How to update the Gateway device library
Note: Gateway device library releases update the device library only, not the Gateway software.
See the EcoStruxure IT Gateway release notes
Device Library v2.0.0.440
September 2023
New device support (Vendor, Series, Type, Protocol)
-
Uniflair/Schneider Electric, FWCV, CRAC, SNMP
Updated devices
-
APC by Schneider Electric, NetShelter Rack PDU, RPDU, SNMP
- Fix blank Name attribute
-
APC by Schneider Electric, Gen 2 Rack PDUs, RPDU, SNMP
- Add per phase Power Factor sensor
- Cisco, Various, Network Switch, SNMP
- Expand alarm support
- Fix missing Model on some devices
- Fix missing Serial Number on some devices
-
Phoenix Contact, QUINT4 DC UPS, UPS, Modbus
- Fix Serial Number issue
-
Schneider Electric, Easy Cooling XDCV, CRAC, Modbus
- Various updates from latest Modbus register map
Device Library v2.0.0.436
August 2023
New device support (Vendor, Series, Type, Protocol)
- Schneider Electric, Easy Cooling XDCV, CRAC, Modbus
-
Vertiv, EXS, UPS, SNMP
Updated devices
-
APC by Schneider Electric, ATS5G, ATS, SNMP
- Fix a firmware related discovery issue. No sensors will appear, however, you will be able to update the firmware which should allow sensors to populate. Delete and rediscovery may be required.
Device Library v2.0.0.426
July 2023
New device support (Vendor, Series, Type, Protocol)
- Schneider Electric, Easy UPS 3S, UPS, Modbus
- Vertiv, CR, CRAC, SNMP
-
Vertiv, CRD010, CRAC, SNMP
Updated devices
- Rittal, LCP (with pCOWeb card), Chiller, SNMP
- Fix scaling on some sensor values
Device Library v2.0.0.418
June 2023
New device support (Vendor, Series, Type, Protocol)
- APC by Schneider Electric, Environmental Management System (legacy), EMS, SNMP
- Phoenix Contact, QUINT4 DC UPS, UPS, Modbus
- Synaccess Networks Inc., SynLink RPDU, RPDU, SNMP
-
Vertiv, PowerSure Interactive 5 UPS, UPS, SNMP
Updated devices
- APC by Schneider Electric, SmartUPS Ultra, UPS, SNMP
- Fix missing outlet group sensors
- HW-group (HWg), STE and STE2, EMS Probe, SNMP
- Use sysName as default for name attribute
-
Juniper, Various, Network Switch, SNMP
- Use sysName as default for name attribute
-
Oracle, RMII Enhanced PDU, RPDU, SNMP
- Fix threshold alarm bug
-
Server Technology Inc. (ServerTech), Sentry4, Rack PDU, SNMP
- Add Unified ID support
- Sinetica, Hawk-i2, Monitoring Unit, SNMP
- Use sysName as default for name attribute
Device Library v2.0.0.409
May 2023
New device support (Vendor, Series, Type, Protocol)
- APC by Schneider Electric, ACRC100 Series, CRAC, Modbus
- APC by Schneider Electric, ACRC300 Series, CRAC, Modbus
- Rittal, LCP (with pCOWeb card), Chiller, SNMP
Updated devices
-
APC by Schneider Electric, ATS5G, ATS, SNMP
- Fix environmental sensor validation
- Fix sensor value scaling for Humidity
-
APC by Schneider Electric, NetShelter Rack PDU, RPDU, SNMP
- Add support for environmental probes
-
Bard, LC6000, CRAC, Modbus
- Additional value scaling fixes
- Riello, Netman 204 (network card), UPS, SNMP
- Additional source for user-defined device name
- Various, UPSMIB, UPS, SNMP
- Fix device names displaying "none"
Device Library v2.0.0.403
April 2023
New device support (Vendor, Series, Type, Protocol)
- HW-group (HWg), STE2, EMS Probe, SNMP
- PowerLogic, HeatTag, EMS Probe, Modbus
- Schneider Electric, Easy UPS SRV, UPS, Modbus
- Vertiv/Liebert, PMP v4 for RDC, Power Meter, SNMP
Updated devices
-
Bard, LC6000, CRAC, Modbus
- Fix bug preventing unit conversions from occurring
-
PowerLogic, Thermal Tag TH110, EMS Probe, Modbus
- Add missing parameters and other improvements
- Various Redfish improvements
Device Library v2.0.0.394
March 2023
New device support (Vendor, Series, Type, Protocol)
-
Bard, LC6000, CRAC, Modbus
- For Modbus register list from manual version 7960-791G
-
Juniper, Various, Network Switch, SNMP
Updated devices
-
Schneider Electric, iEM3000 Series, Power Meter, Modbus
- Fix alarm bug
-
Rittal, CMC-TC, Monitoring System, SNMP
- Fix device name attribute
-
Schneider Electric, Gutor BMS BACS, Battery Management System, SNMP
- Fix missing battery modules
-
Cisco, Various, Network Switch, SNMP
- Expand sensor support
Device Library v2.0.0.382
February 2023
New device support (Vendor, Series, Type, Protocol)
-
Lenovo, XCC BMC, Server, Redfish
Updated devices
-
CyberPower, Smart App Series, UPS, SNMP
- Fix device discovery bug
-
Rittal, CMC-TC, Monitoring System, SNMP
- Fix missing units on some sensor values
- Add support for "Battery Health Alarm Sleep Time" and "Battery Health Alarm Warning Time" parameters
-
Uniflair by Schneider Electric, Various, Modbus/SNMP
- Alarm severity updates
Device Library v2.0.0.372
December 2022
New device support (Vendor, Series, Type, Protocol)
- ComAp, InteliLite NT MRS, Genset Controller, Modbus
- Cummins, PowerCommand 500 Series (ATS), ATS, Modbus
- Fronius, Symo Hybrid, Inverter, Modbus
- Generac, D100 H-Panel, Genset Controller, Modbus
- Proges Plus, Sensor Net Connect (POI0010), EMS, SNMP
- Schneider Electric, iEM3000 Series, Power Meter, Modbus
- Schneider Electric, VarPlus Logic VL6, Power Meter, Modbus
- Schneider Electric, Vigilohm IM400, Insulation Monitoring Device (implemented as "generic" device in IT Gateway/IT Expert), Modbus
- Uniflair by Schneider Electric, Uniflair LE Direct Expansion (Gen 2), CRAC, Modbus
- Uniflair by Schneider Electric, Uniflair AM SDCx/SUCx (with Carel pCOC/MP20II), CRAC, Modbus
Updated devices
-
APC by Schneider Electric, Smart-UPS (SUMX), UPS, SNMP
- Add support for "Battery Health Alarm Sleep Time" and "Battery Health Alarm Warning Time" parameters
-
APC by Schneider Electric, APC SmartUPS (SMT/SMX/SURTD/SRT), UPS, Modbus
- Expand alarm support
- Add support for UPS Efficiency and Efficiency Status parameters
-
Cisco, Various, Network Switch, SNMP
- Fix a bug where portions of some sensor names display as "null"
-
Schneider Electric, Easy UPS 3M, UPS, Modbus
- Remove "Inverter Supply Power" alarm and reimplement as a state sensor instead
-
Vertiv/Liebert, Various, SNMP
- When lgpConditionType OID returns "alarm" or "fault" and lgpConditionSeverity OID returns "not-applicable", we will report the alarm severity as a critical instead of informational
Device Library v2.0.0.348
November 2022
New device support (Vendor, Series, Type, Protocol)
- Rittal, CMC-TC, Monitoring System, SNMP
-
APC by Schneider Electric, UPS, Modbus
- Galaxy VL 200/500 kW
- Galaxy VS/PX 10-100 kW
- Symmetra PX 20-160 kVA (NMC2 firmware application sy3p and px2 v6.5.0+)
- Symmetra PX 250/500 kVA
-
Basler, DGC-2020 (non-legacy), Genset Controller, Modbus
- DGC-500/DGC-1000 upgrade/replacement
Updated devices
-
APC by Schneider Electric, NetShelter 10000 Series, RPDU, SNMP
- Fix breaker Load State and Current sensor issue
-
Liebert/Vertiv, MPH/MPHR/MPX, RPDU, SNMP
- Add daisy chaining support
- Expand Unified ID support
- PowerLogic by Schneider Electric, ION9000 Series, Power Meter
- Update various sensor names and groups
-
SICES, GC310, Genset Controller, Modbus
- Fix Engine Coolant Temperature value scaling
Device Library v2.0.0.334
November 2022
New device support (Vendor, Series, Type, Protocol)
- SICES, GC310, Genset Controller, Modbus
Updated devices
-
APC by Schneider Electric, NetShelter 10000 Series, RPDU, SNMP
For discovered devices, there will be loss of historical data on breaker and switched outlet sensors due to necessary updates to add Network Port Sharing (NPS) support
- Add support for metered outlet measurements and alarms
- Fix discovery failure while using Network Port Sharing feature
- Fix labels that returned as hexadecimal strings
-
Various, Modbus/SNMP
- Update unique identifiers incorrectly reporting as "Serial Number" to be "Identifier" instead
Device Library v2.0.0.328
October 2022
New device support (Vendor, Series, Type, Protocol)
- Redetec, PN/3.0/Red/FAL, Fire Suppression System, Modbus
- Uniflair by Schneider Electric, Uniflair Room Cooling (Gen2), CRAC, SNMP
Updated devices
-
Schneider Electric, Easy UPS 3M, UPS, Modbus
-
Registers defined for the following parameters were corrected:
- Serial Number
- Firmware Version
- Air Filter Maintenance Cycle (Month)
- Air Filter Maintenance Time
- Battery Running Time
-
Registers defined for the following parameters were corrected:
-
Luminous/Various, Various, UPS, SNMP
-
Various fixes to improve data quality
- This SNMP MIB is used by multiple vendors.
This change affects devices that use the following OID tree:
.1.3.6.1.4.1.43943.1.1
- This SNMP MIB is used by multiple vendors.
-
Various fixes to improve data quality
Device Library v2.0.0.311
September 2022
New device support (Vendor, Series, Type, Protocol)
- Schneider Electric, Easy UPS 3M, UPS, Modbus
-
Schneider Electric, Galaxy PW, UPS, Modbus
- For devices using JBus/Modbus Communication Card
- Schneider Electric, Galaxy VM (3:3 50-225kVA 400/480V), UPS, Modbus
- Schneider Electric, EVlink EV Charger, EV Charger, Modbus
Device Library v2.0.0.305
September 2022
New device support (Vendor, Series, Type, Protocol)
- ASCO, Power Manager Xp 7000 Series, Power Meter, Modbus
- Circutor, CVM-NRG96, Power Meter, Modbus
- Cummins, PowerCommand 500 Series, Genset Monitor, Modbus
- CyberPower, Switched/Metered ATS, ATS, SNMP
- Uniflair by Schneider Electric, Various, CRAC, SNMP
- Support added for the following devices equipped with Carel pCOWeb communication cards utilizing "custom OID" firmware:
- Uniflair AM SDCx/SUCx with pCO1 and UG40
- Uniflair AM SDxx/SUxx with pCO1 and UG40
- Uniflair LE TDCV/TUCV with pCO1 and UG40
- Uniflair LE Txxxxx11/Txxxxx21/Txxxxx22/Txxxxx42 with pCO1 and UG40
- Support added for the following devices equipped with Carel pCOWeb communication cards utilizing "custom OID" firmware:
Updated devices
- Cisco, Various, Network Switch, SNMP
- Add port-level sensors
- Riello, NetMan 204, UPS, SNMP
- Add a fallback for the UPS name attribute
-
Tripp Lite, WEBCARDLX Devices, Various, SNMP
-
Fix discovery failure on devices not reporting a serial number over SNMP
- For devices using PowerAlert 20.x.x firmware, make sure you have a "Monitor" role set up under "SNMP Users". For more information, please refer to the PowerAlert Device Manager (PADM) 20.0.0 User's Guide
-
Fix discovery failure on devices not reporting a serial number over SNMP
Device Library v2.0.0.288
August 2022
New device support (Vendor, Series, Type, Protocol)
- FG Wilson, PowerWizard 2.x/3.x, Generator Set Controller, Modbus
- Liebert/Vertiv, XDC Chiller and Pumping Unit, Chiller, SNMP
Updated devices
- APC by Schneider Electric, SmartUPS, UPS, Modbus
- Fix incorrect Battery Age
-
Caterpillar, EMCP4, Genset Monitor, Modbus
- Added alarm support
Device Library v2.0.0.277
July 2022
New device support (Vendor, Series, Type, Protocol)
- Raritan, PX iPDU, RPDU, SNMP
- Liebert/Vertiv, Challenger Cooling System, CRAC, SNMP
- Soler & Palau (S&P), DOMEO 210 FL 3V EU, Heat Recovery Unit, Modbus
- Schleifenbauer/Daxten, hPDU, RPDU, SNMP
Updated devices
- Liebert/Vertiv, MPX Rack PDU, RPDU, SNMP
- Add support for environmental sensor
- Fix sensor mapping bug in IT Expert for environmental sensors
- Add support for environmental sensor
- Eaton, Various, UPS, SNMP
- Fix a bug where some devices discover, but present no sensors
- Uniflair by Schneider Electric, Various, CRAC/Chiller, SNMP/Modbus
- Alarm severity updates
- Tripp Lite, SNMPWEBCARD, RPDU/UPS, SNMP
- Expand Unified ID support
- NetBotz by Schneider Electric, NetBotz 250, EMS, SNMP
- Add 0-5v sensor support
Device Library v2.0.0.264
June 2022
New device support (Vendor, Series, Type, Protocol)
- Carrier, AquaSnap, Chiller, Modbus
- Liebert/Vertiv, PPC Distribution Cabinet, PDU, SNMP
- Liebert/Vertiv, PDX/PCW Large CRAC, CRAC, SNMP
- Nortec, Humidifier, Generic, Modbus
- Schneider Electric, EcoBreeze, CRAC, Modbus
- Sensatronics, Model U Universal Monitor, EMS, SNMP
- Uniflair by Schneider Electric, Various, CRAC/Chiller, SNMP
- Support added for the following devices equipped with Carel pCOWeb communication cards utilizing "custom OID" firmware:
- LRACx/LRAHx with Carel pCOXS
- BRRCx/BRWCx/BRWHx with Carel pCO1 and MP20II
- BRECx/BREFx with pCO1 and MP20II
- BRACx/BRAFx/BRAMx/BRATx with pCO1 and MP20II
- BCWCx with pCO3 and UG50
- BCECx/BCEFx with pCO5 and UG50
- Support added for the following devices equipped with Carel pCOWeb communication cards utilizing "custom OID" firmware:
Updated devices
- APC by Schneider Electric, InfraStruxure PDU, PDU, SNMP
- Add ITA support for circuit meter breakers
- Liebert/Vertiv, Rack PDU 2, RPDU, SNMP
- Add support for environmental sensors
Device Library v1.14.0.62
Requires EcoStruxure IT Gateway version 1.14
May 2022
New device support (Vendor, Series, Type, Protocol)
- CyberPower, Smart App Series, UPS, SNMP
- Riello, Netman 204, UPS/ATS/STS, SNMP
- Tripp Lite, SR(X) COOL, CRAC, SNMP
Updated devices
- APC by Schneider Electric, Easy UPS 3S/3M, UPS, SNMP
- Add Battery Temperature sensor
- APC by Schneider Electric, PowerChute Network Shutdown, Software, SNMP
- Various improvements
- APC by Schneider Electric, Various Smart-UPS, UPS, SNMP
- Modify Output Total Percent Load and Output Total Percent Power sensor labels to include measurement units
- Add Output Efficiency sensor occurring under certain discovery conditions
- Improvement for devices equipped with battery string/block monitoring
- Add sensor for Time Since Last Battery Replace
- APC by Schneider Electric, Remote Power Panel (RPP), PDU, SNMP
- Add Hardware Revision attribute
- Application Version attribute being reported as Firmware Version
- APC by Schneider Electric, NetShelter Rack PDU, RPDU, SNMP
- Various improvements
- APC by Schneider Electric, InRow RD 100 Series, CRAC, SNMP
- Add attributes for Firmware Version and Hardware Version
- Dell, Server, Redfish
- Various improvements
- NetBotz by Schneider Electric, NetBotz 750, EMS, SNMP
- Added 0-5v sensors
- NetBotz by Schneider Electric, NetBotz 250, EMS, SNMP
- Added new sensors
- NetBotz by Schneider Electric, NetBotz 200, EMS, SNMP
- Fix temperature sensor scaling
- Samsung/Schneider Electric, Samsung BMS/Schneider Electric Lithium Ion Batteries, BMS, Modbus
- Various improvements
Device Library v1.14.0.46
Requires EcoStruxure IT Gateway version 1.14
April 2022
New device support (Vendor, Series, Type, Protocol)
- Liebert/Vertiv, Liebert NX/SX - Chloride ManageUPS Net Adapter, UPS, Modbus
- Eaton, ATC-900, ATS, Modbus
Updated devices
- CyberPower, ePDU, RPDU, SNMP
- Add environmental sensor support
- Uniflair, Various, CRAC/Chiller, SNMP
- Add sensor validation check for "-858993460" to all sensors
Device Library v1.14.0.40
Requires EcoStruxure IT Gateway version 1.14
March 2022
New device support (Vendor, Series, Type, Protocol)
- Carel, IR33, CRAC, Modbus
- Legrand, Various, UPS, Modbus
- Support added for the following models:
- Daker DK/Daker DK Plus
- Keor LP/Keor S/Keor Line RT
- Dhea
- Whad 800-2500/Whad CAB
- Megaline
- Niky/Niky S
- Support added for the following models:
Updated devices
- APC by Schneider Electric, NetShelter RPDU, RPDU, SNMP
- Remove invalid "Power - Bank" sensors
- APC by Schneider Electric, Power Management Module (PMM), SNMP
- Add support for "Input Max Instantaneous Neutral Current" parameter
- APC by Schneider Electric, Various SmartUPS, UPS, SNMP
- Add support for "Battery Health Alarm Warning Time" and "Battery Health Alarm Sleep Time" parameters
- Add support for "High Transfer Voltage" and "Low Transfer Voltage" thresholds
- Add support for "Time Since Input Energy Usage Timer Last Reset" parameter
- Rename "Time Since Last Timer Reset" parameter to "Time Since Output Energy Usage Timer Last Reset"
- Deep Sea Electronics, DSE72xx/DSE61xx/DSE74xx, Generator Control Module, Modbus
- Convert "Warning Alarm Active" alarm to a state sensor and remove alarm
- Fix "Control Unit Failure" alarm bug
- PowerLogic, Power Meter, PM5000 Series, Modbus
- Various updates and bug fixes
Device Library v1.14.0.30
Requires EcoStruxure IT Gateway version 1.14
March 2022
New device support (Vendor, Series, Type, Protocol)
- Woodward, DTSC-200, Automatic Transfer Switch (ATS), Modbus
Updated devices
- APC by Schneider Electric, Various SmartUPS, UPS, SNMP
- Add Lower/Upper Output Voltage Tolerance sensors
- Resolved issue related to Number of External Battery Packs and and Number of Battery Cabinets sensors
- Add Output Voltage sensor to some devices
- APC by Schneider Electric, Remote Power Panel (RPP)/Power Management Module (PMM), SNMP
- Resolved issue related to Circuit Alarm Generation and Circuit Breaker State sensors
- APC by Schneider Electric, NetBotz 250, EMS, SNMP
- Use high precision pod probe temperature when available
- Samsung/Schneider Electric, Battery Manager, Modbus
- Various alarm updates
- Resolved issue related to Cell Temperature scaling
Device Library v1.14.0.19
Requires EcoStruxure IT Gateway version 1.14
February 2022
Updated devices
- APC by Schneider Electric, SmartUPS, UPS, SNMP
- Fix incorrect Output Voltage scaling on some devices
- Fix incorrect state on System Status sensor
- Fix log spam on devices that have Battery Packs/Cartridges
Device Library v1.14.0.16
Requires EcoStruxure IT Gateway version 1.14
February 2022
New device support (Vendor, Series, Type, Protocol)
- Advance Cooling Systems (ACS), Panel Air Conditioner, CRAC, Modbus
- Hewlett Packard Enterprise (HPE), PDU3, RPDU, SNMP
- Vertiv, APM, UPS, Modbus
Updated devices
- APC by Schneider Electric, Gen 2 RPDU, RPDU, SNMP
- Add per-phase sensors for Load State and Peak Current
- APC by Schneider Electric, Micro Data Center, Micro Data Center, SNMP
- Remove power meter sensors returning "-1" for values
- Remove UPS sensors returning "-1" for values
- Eaton, Powerware UPS, UPS, SNMP
- Add attributes for Firmware Revision and SKU
- Fix missing serial number attribute on some devices
- Update alarm severities
- Add network card component
- Gutor by Schneider Electric, Gutor SDC, Charger/Rectifier, SNMP
- Add new state for "Output Status"
- Uniflair by Schneider Electric, Various, CRAC, SNMP & Modbus
- Fix ITA related bug for "Run Hours" sensors
- Vertiv, Various, Various, SNMP
- Expand ITA support
- Fix missing "System Output Power Phase" sensors on NX225-600k UPS's and add ITA support for those sensors
Device Library v1.13.0.53
Requires EcoStruxure IT Gateway version 1.13
January 2022
New device support (Vendor, Series, Type, Protocol)
- MGE, Upsilon, STS, Modbus
- Eltek, Smartpack S/Smartpack2, Controller, SNMP
- Panduit, G5 iPDU, RPDU, SNMP
- General Electric (GE), LP Series UPS, UPS, SNMP
- Elcos, Various, Generator, Modbus
- Schneider Electric, Com’X 510, Gateway, Modbus
- APC by Schneider Electric, SmartUPS Ultra, UPS, SNMP
Updated devices
- APC by Schneider Electric, Various, UPS, SNMP
- Fix Battery Age sensors that report a default value of 01/01/2000
- Fix missing Time On Battery sensor
- Remove redundant Battery Check Recommended warning event
- Fix scaling for Time Running On Battery on some devices
- Fix phase nomenclature on Galaxy VS devices
- APC by Schneider Electric, Rack PDU Gen 2, RPDU, SNMP
- Add Location attribute
- Fix incorrect/missing Apparent Power data on daisy-chained devices
- APC by Schneider Electric, Micro DC, Micro Data Center, SNMP
- Fix bug where Application Version and AOS Version attributes did not update in ITE after updating the firmware
- APC by Schneider Electric, Power Management Module (PMM), PDU, SNMP
- Fix bug where Firmware Version and AOS Version attributes did not update in ITE after updating the firmware
- APC by Schneider Electric, NetBotz 250, EMS, SNMP
- Fix missing Pod Door Sensor
- Uniflair by Schneider Electric, TSAx/TRAx with 7-inch touchscreen, Chiller, SNMP
- Fix Compressor 2 Output sensor label displaying as duplicate Compressor 1 Output sensor
- Geist, Upgradeable/R-Series v5.0 PDU, RPDU, SNMP
- Fix bug where all outlet names were “Outlet 2”
Device Library v1.13.0.33
Requires EcoStruxure IT Gateway version 1.13
December 2021
New device support (Vendor, Series, Type, Protocol)
- APC by Schneider Electric, ATS5G, ATS, SNMP
- Dell, iDRAC (iDRAC-SMIv2 MIB), Server, SNMP
- Uniflair by Schneider Electric, XRAC/XRAF, Chiller, Modbus
Updated devices
- Uniflair by Schneider Electric, ERAx/ERCx pCO1/MP20II, Chiller, SNMP/Modbus
- Add fan type to all "Unit Type" sensor enumerations
- APC by Schneider Electric, Microlink, UPS, SNMP
- Add support for Battery Pack sensors
- Samsung/Schneider Electric, Samsung BMS/Schneider Electric Lithium Ion Batteries, BMS, Modbus
- Add support for cell level sensors
- APC by Schneider Electric, NetBotz Rack Monitor 200/250, EMS, SNMP
- Extend ITA support to wireless probes
Device Library v1.13.0.26
Requires EcoStruxure IT Gateway version 1.13
December 2021
New device support (Vendor, Series, Type, Protocol)
-
Alpha Technologies, Cordex CXC, System Controller, SNMP
- Caterpillar, EMCP 4, Genset Monitor, Modbus
- Delta Energy Systems, PSC 1000, System Controller, SNMP
- Schneider Electric, PowerChute Network Shutdown (PCNS), UPS Management, SNMP
- Socomec, STATYS XS, Transfer Switch, SNMP
Updated devices
-
APC, SmartUPS (various), UPS, SNMP
- Fix bugs related to Output Voltage, Output Current, Output Active Power, and Output Total Apparent Power
- Fix Output Active Power returning -1
-
Liebert/Vertiv, Power Management Panel (PMPv4), Power Meter, SNMP
- Support for additional models
-
Monico, mCore SDR, Genset, Modbus
- Add support for second generator
- Make -1 the default "invalid" value
-
Raritan, PDU2, Rack PDU, SNMP
- Fix errors spamming console log
-
Schneider Electric, Easy PDU ("EPDU" SKU), Rack PDU, SNMP
- Various bug fixes
-
Schneider Electric, Easy UPS 3PH, UPS, SNMP
- Add 3-phase Output Apparent Power, Total Output Apparent Power, and Total Output Apparent Power Percentage measurements with support for ITA
-
Server Technology Inc. (ServerTech), Sentry4, Rack PDU, SNMP
- Various bug fixes
-
Uniflair by Schneider Electric, InRow RD (ACRD600), CRAC, SNMP
- Add Return Humidity sensor
- Add Humidifier Water Conductivity sensor
Device Library v1.13.0.13
Requires EcoStruxure IT Gateway version 1.13
November 2021
New device support (Vendor, Series, Type, Protocol)
- Liebert/Vertiv, Power Management Panel (PMPv4), Power Meter, SNMP
- Monico, mCore SDR, Genset, Modbus
- PowerLogic by Schneider Electric, PM800 Series (using PM8ECC communication module), Power Meter, SNMP
- PowerLogic by Schneider Electric, HDPM, BCM, SNMP
- PowerLogic by Schneider Electric, BCMP (3-Phase), BCM, Modbus
- Socomec, Delphys GP, UPS, SNMP
- Vertiv, Netsure Rectifier, Rectifier, SNMP
Updated devices
- APC, Smart-UPS, UPS, SNMP
- Fix Output Efficiency returning negative percentage values
- Fix some devices that are missing Input Phase Count/Output Phase Count attributes
- APC, Various CRACs/Chillers, CRAC/Chiller, SNMP - Fix scaling issues on some sensors
- Liebert, Various, Various, SNMP - Fix "Info" level alarms reporting as "Critical"
- Various, UPSMIB, UPS, SNMP - Add a fallback for missing name and/or model attributes on some devices
Device Library v1.12.0.14
Requires EcoStruxure IT Gateway version 1.12
October 2021
New device support (Vendor, Series, Type, Protocol)
- Black Box, AlertWerks ServSensor, EMS, SNMP
- Tripp Lite, WEBCARDLX UPS, UPS, SNMP
- Uniflair/Schneider Electric, XRAC/XRAF, Chiller, SNMP
- Uptime Devices, Sensor Hub, EMS, SNMP
Updated devices
-
Airedale, EasiCool EZRE Precision Air Conditioning (DF35X-EZRE-1, pCOWeb), CRAC, SNMP
- Add "Unit Status" sensor
- Remove "General Alarm"
- APC, Smart-UPS, UPS, SNMP - Fix Output Frequency sensor returning "-" instead of frequency measurement.
- Cisco, Various, Network Switch, SNMP
- Change device type from "generic" to "ip switch"
- Add firmware version attribute
- Add chassisMinorAlarm/chassisMajorAlarm/chassisTempAlarm as alarms
- Eaton, EMS-PDU, RPDU, SNMP - Fix discovery issue with PXGX PDP
- Eaton, Powerware UPS, UPS, SNMP - Fix scaling issue on Input Power - Phase # sensor for some devices
- Schneider Electric, NetBotz 750, SNMP - Add firmware version attribute
- Various, Various, UPS, SNMP - Codified "Battery Age" and "UPS Age" on numerous devices to better support analytics.
Device Library v1.12.0.4
Requires EcoStruxure IT Gateway version 1.12
September 2021
New device support (Vendor, Series, Type, Protocol)
- Uniflair/Schneider Electric, XRAC/XRAF, Chiller, SNMP
- APC/Schneider Electric, Easy RPDU Gen. 2 (MBO/SMBO), RPDU, SNMP
- Emerson/Liebert/Vertiv, GXT4, UPS, SNMP
- Emerson/Liebert/Vertiv, GXT5, UPS, SNMP
- Emerson/Liebert/Vertiv, NX225k-600k, UPS, SNMP
Updated devices
- APC/Schneider Electric, Easy UPS, UPS, SNMP - Fix unsupported Battery Current sensors returning 32767/-32767
- APC/Schneider Electric, InfraStruXure PDU (xPDU), PDU, SNMP - Add support for Breaker Panel Energy Usage and Power sensors.
- Uniflair/Schneider Electric, Uniflair LE L, CRAC, SNMP - Add support for Actual Speed Fan 1-4 sensors
-
APC/Schneider Electric, Various, UPS, SNMP
- Remove sensors that return "-1"
- Modify Battery Block sensor names to include its associated Battery String
- Square D, MicroLogic, Breaker, Modbus - Remove sensors that return "-32768"
- APC/Schneider Electric, Modular PDU (MPDU), PDU, SNMP - Add support for Input Contacts and Output Relays
-
PowerLogic, PM53xx, Power Meter, Modbus
- Add Apparent Energy and Reactive Energy Delivered +/- Received sensors
- Various fixes
Device Library v1.11.0.21
Requires EcoStruxure IT Gateway version 1.11
September 2021
IMPORTANT: If you have a Modbus device that has been discovered with Type: UPS, Vendor: MGE, Family: MgeGalaxyUps you will need to rediscover the device with the following:
Type: UPS, Vendor: MGE, Family: mgeGalaxy_300_7000
New device support (Vendor, Series, Type, Protocol)
- APC/Schneider Electric/MGE, Galaxy 5000/5500, UPS, Modbus
- Uniflair/Schneider Electric, AquaCentr Gen 2 (Model BCW* with NMC), Chiller, SNMP
-
Uniflair/Schneider Electric, "Telnew" (MB/SP/WM) with custom OID 99053, CRAC, SNMP
- This is for Uniflair MB/SP/WM devices equipped with a Carel pCO1 web card and UG40 HMI using the custom enterprise OID "99053" instead of the standard Carel enterprise number "9839".
- Komfovent, Verso-CF, CRAC, Modbus
- CyberPower, ePDU, RPDU, SNMP
- Eaton, Rack Monitor (v2.00), EMS, SNMP
Updated devices
-
APC/Schneider Electric, Easy UPS, UPS, SNMP - Fix missing serial number attribute on some models
- APC/Schneider Electric, ACRD 300 Series, CRAC, SNMP - Fix Delta-T Setpoint sensor
- Various, PPC UPS (Upsmate.mib), UPS, SNMP - Add Battery Age sensor. This is for devices/vendors that use the "Upsmate" SNMP MIB, which includes many Easy UPSs
- Emerson/Liebert/Vertiv, eXM M/S/R, UPS, SNMP - Fix missing temperature sensors/alarms
- Emerson/Liebert/Vertiv, Various, Various, SNMP - Support for newest models added to the lgpProductSpecific OID table
- Emerson/Liebert/Vertiv, Various, Various, SNMP - Update default alarm severity for alarms that cannot be mapped properly
-
Grundfos, CIM 500, Pump, Modbus
- Fixed register offset issue
- Fix scaling for temperature sensors
- Add check for invalid sensors (value of 65535)
- Chatsworth, eConnect PDU (Previous Model/Legacy), RPDU, SNMP - Now reads the name attribute when it does not use the user-defined name.
Device Library v1.11.0.3
Requires EcoStruxure IT Gateway version 1.11
August 2021
New device support (Vendor, Series, Type, Protocol)
-
APC/Schneider Electric, 10000 Series Rack PDU (APDU10000), RPDU, SNMP
-
Airedale, EasiCool EZRE Precision Air Conditioning (DF35X-EZRE-1, pCOWeb), CRAC, SNMP
-
AKCP, sensorProbe Plus Series (sensorProbe+), EMS, SNMP
-
Emerson/Liebert/Vertiv, eXM M/S/R, UPS, SNMP
-
Grundfos, CIM/CIU 500, Pump, Modbus
-
Kidde-Fenwal Inc., ARIES, Fire Suppression System, Modbus
-
Kohler, Decision-Maker 3000, Generator, Modbus
-
Stulz, SplitAir3, CRAC, Modbus
Updated devices
-
APC/Schneider Electric, Easy UPS SRV, UPS, SNMP - Add phase information to sensor labels for 3 phase models.
-
APC/Schneider Electric, Microlink Smart-UPS, UPS, SNMP - Add monitoring support for battery packs
-
APC/Schneider Electric, ACRD300 Series, CRAC, SNMP - Fix Application Version attribute showing Firmware Version
-
Schneider Electric, Gutor BMS BACS, Battery Management System, SNMP - Add support for BACS Module State alarms
-
Schneider Electric/PowerLogic, Various, Power Meter, Modbus - Fix vendor names so they all display as "Powerlogic" on discovery page instead of "Powerlogic" and "Power_logic".
IMPORTANT: This update requires manual rediscovery of devices that have "Power_logic" as the vendor. Devices will go offline after the device library is updated, and will stay offline until you run a rediscovery. Affected families include:
- Cm3000/Cm4000
- Ion8600
- Pm210
- Pm32xx
- Pm53xx
- Pm55xx
- Pm620
- Pm710
- Pm750
- Pm8000
- Pm8xx
- Enercept
- Ion6200
- Ion7650
-
Chatsworth, eConnect PDU (Previous Model/Legacy), RPDU, SNMP - Restructure breaker configuration within the DDF to be more accurate and include additional Unified ID support.
IMPORTANT: Significant changes were made to this DDF which will cause loss of historical data on sensors after the device library is applied.
-
Enlogic, Legacy MIB (ENLOGIC-PDU-MIB), RPDU, SNMP - Add alarm support
Device Library v1.10.0.52
Requires EcoStruxure IT Gateway version 1.10
August 2021
New device support (Vendor, Series, Type, Protocol)
- Electro Industries/GaugeTech Inc., Shark 200, Power Meter, Modbus
Updated devices
- ServerTech, Sentry4, RPDU, SNMP - Fix alarm bug
- Rittal, CMCIII, Monitoring System, SNMP - Update Name attribute OID
- APC, Symmetra, UPS, SNMP - Add APC Power Module monitoring support
-
APC, Remote Power Panel (RPP), PDU, SNMP - Add support for the following parameters:
-
Input average current (1.3.6.1.4.1.318.1.1.28.3.1.2.1.25)
-
Neutral current (1.3.6.1.4.1.318.1.1.28.3.1.2.1.26)
-
Max Instantaneous current (1.3.6.1.4.1.318.1.1.28.3.1.3.1.9)
-
Current phase angle data (1.3.6.1.4.1.318.1.1.28.3.1.3.1.10)
-
Voltage THD L to N (1.3.6.1.4.1.318.1.1.28.3.1.3.1.12)
-
Voltage THD L to L (1.3.6.1.4.1.318.1.1.28.3.1.3.1.11)
-
Energy usage accumulated total (1.3.6.1.4.1.318.1.1.28.3.1.2.1.34)
-
Average Voltage L to N (1.3.6.1.4.1.318.1.1.28.3.1.2.1.30)
-
Load percentage : (1.3.6.1.4.1.318.1.1.28.3.1.2.1.31)
-
Energy Usage reset Date for input (1.3.6.1.4.1.318.1.1.28.3.1.2.1.38).
-
Energy Usage Reset Date for panels (1.3.6.1.4.1.318.1.1.28.3.3.3.1.12)
-
Input1 Voltage Line to Line Average (1.3.6.1.4.1.318.1.1.28.3.1.2.1.29)
-
Current THD (1.3.6.1.4.1.318.1.1.28.3.1.3.1.13)
-
Phase loss threshold (1.3.6.1.4.1.318.1.1.28.3.1.2.1.35)
-
Input x Phase Loss : 1.3.6.1.4.1.318.1.1.28.3.1.2.1.51
-
Input x Breaker CT Size : 1.3.6.1.4.1.318.1.1.28.3.1.2.1.36
-
Input x Breaker rating : 1.3.6.1.4.1.318.1.1.28.3.1.2.1.37
-
Panel Channel Branch Number : 1.3.6.1.4.1.318.1.1.28.3.3.3.1.34
-
Panel Channel CT Size : 1.3.6.1.4.1.318.1.1.28.3.3.3.1.35
-
Phase association : 1.3.6.1.4.1.318.1.1.28.3.3.3.1.4
-
Number of poles : 1.3.6.1.4.1.318.1.1.28.3.3.3.1.3
-
Alarm generation : 1.3.6.1.4.1.318.1.1.28.3.3.3.1.21
- Fix Input Frequency Deviation sensor
-
-
Uniflair, Various, CRAC/Chiller, SNMP/Modbus (pCOWeb/non-NMC)
- Add missing alarms
- Convert "Type A/Type B/Type C" alarms to sensors
- Eaton, Access Power Solutions (APS), Inverter, SNMP - Update Serial Number and Name attribute OIDs
Device Library v1.10.0.41
Requires EcoStruxure IT Gateway version 1.10
July 2021
New device support (Vendor, Series, Type, Protocol)
- APC/Schneider Electric, Easy Micro Data Center, Micro Data Center, SNMP
-
Uniflair/Schneider Electric, Aquascroll with custom OID 99009, Chiller, SNMP
- This is for Aquascroll devices equipped with a Carel pCO5+ web card and UG50 HMI using the custom enterprise OID "99009" instead of the standard Carel enterprise number "9839".
- AKCP, SensorProbe Series, EMS, SNMP
- Alpha, FXM, UPS, SNMP
- Cisco, Various, Network Switch, SNMP
-
Eaton, Access Power Solutions (APS), Inverter, SNMP
- Uses SC200 communication card
- HWGroup, HWg-STE, Environmental Probe, SNMP
- PDI, PowerPak PDU w/ WaveStar/FDI Display, PDU, SNMP
- PDI, WaveStart STS, Static Transfer Switch, SNMP
- Redetec, PN/3.0/Red/FAL, Fire Suppression System, SNMP
Updated devices
- APC/Schneider Electric, Netbotz, EMS, Botzspeak - Add “value rising too quickly” and “value dropping too quickly” alarms
- APC/Schneider Electric, NetBotz 250, EMS, SNMP - Fix temperature conversion for wireless sensor
- Uniflair/Schneider Electric, Aquascroll, Chiller, SNMP/Modbus - Support for additional alarms
-
Schneider Electric, Masterpact MTZ, Power Meter, Modbus
- Add serial number attribute
- Fix scaling on energy sensors
- Add serial number attribute
-
PowerLogic/Schneider Electric, PM8000, Power Meter, Modbus
- Add sensors for per-phase/neutral Current Demand, Active Power Demand, Reactive Power Demand, and Apparent Power Demand
- Use 64-bit registers for Active Energy Delivered, Reactive Energy Delivered, and Apparent Energy Delivered
- Fix some scaling issues
- PPC, UPS, SNMP - Add fix to better handle single phase devices and added missing "Output Load" sensor
Device Library v1.9.0.236
April 2021
New device support (Vendor, Series, Type, Protocol)
- Oracle, RMII Enhanced PDU, RPDU, SNMP
-
Schneider Electric/Uniflair, ERAx/ISAx with custom OID 99001, Chiller, SNMP
- This is for ERAx and ISAx devices equipped with a Carel pCO1 web card and MP20II HMI using the custom enterprise OID "99001" instead of the standard Carel enterprise number "9839".
Updated devices
- Schneider Electric, APC, Gen 2 RPDU, SNMP - Updated “Total Power” sensor name to “Total Input Power”.
- Schneider Electric, PowerLogic, PM800, Modbus - Fix scaling on power sensors.
- APC by Schneider Electric, NetBotz - Temperature and dew point alarms for NetBotz series 200, 300, and 400 devices can now be displayed in the Gateway in Fahrenheit or Celcius. NetBotz series 200, 300, and 400 devices use the Botzspeak protocol.
-
TrendPoint, EnerSure, BCM, SNMP - Fixed discovery issue present on EnerSure devices.
-
Schneider Electric, Gutor, SDC, Modbus - Fixed state sensor enumerations for “Operation Mode” and “Active Systems”.
- ASCO, 5140 Quad Ethernet Module (72EE), SNMP - Fixed discovery issue present on some devices.
- Deep Sea Electronics, DSE74xx, Generator Control Module, Modbus - Added support for 7450 and hide unsupported sensors instead of showing incorrect values
Device library v1.9.0.227
April 2021
- Schneider Electric, APC, Symmetra 3P, UPS, SNMP - Added sensors for the power module.
- Schneider Electric, APC, Easy UPS 3 Phase with NMC, SNMP - Added battery age sensor.
- Schneider Electric, PowerLogic, PM8000, Power Meter - Added additional sensors.
- Schneider Electric, ComPact NSX, Breaker, Modbus - Added name and serial number attributes.
- Geist, Watchdog, Environmental Monitor, SNMP - Fixed discovery issue with certain models.
Device library v1.9.0.218
March 2021
- ASCO, 72EE, ATS, (5140 Quad Ethernet Module), SNMP
- Liebert, iCOM SC type HPC, Chiller, SNMP
- Liebert, iCOM PA type PEXS, Chiller, SNMP
- Schneider Electric, Uniflair, Aquascroll
- Modbus - Some alarm severities were updated from warning to critical.
- Updated Compressor Inverter Operative Limits enumerations
- APC by Schneider Electric
- InfraStruxure PDU - Added Unified ID support
- Smart UPS - Added Output Active Power sensor to some devices
- Smart UPS - Added Unified ID support to Power Module sensors
- NetBotz 755, Environmental Monitor - Fixed missing temperature and humidity sensors
- All UPSs with NMCs - New sensor for Total DC Current. Removed Total DC Current as a back up to Battery Current.
- PowerLogic, PM8000, Power Meter - Fixed Modbus register addressing issue
Device library v1.9.0.201
February 2021
- Schneider Electric, Easy UPS 3S, SNMP
- Schneider Electric, PowerLogic ION9000, Power Meter, Modbus
- Enlogic, iPDU, SNMP
- Schneider Electric, Uniflair, Aquascroll, SNMP - Some alarm severities were updated from warning to critical.
- Schneider Electric, Uniflair, UG40 MP40, SNMP - Some alarm severities were updated from warning to critical.
- Schneider Electric, Easy UPS 3M, SNMP - Some devices were not retrieving the serial number in previous versions.
Device library v1.9.0.193
February 2021
- Schneider Electric, Sepam T40, Protective Relay, Modbus
- Schneider Electric, Sepam Series 80, Protective Relay, Modbus
- Cummins, PowerCommand 2.x/3.x, Generator Control Module, Modbus
- Cummins, PCC 1301, Generator Control Module, Modbus
- Deep Sea Electronics, DSE7420, Generator Control Module, Modbus
- Green Revolution Cooling, Immersion Cooling, Modbus
- HIMOINSA, CEC/CEM/CEA, Generator Control Module, Modbus
- Siemens, Sentron 3200, Power Meter, Modbus
- Sinetica, Hawk-i2, Monitoring Unit, SNMP
- Schneider Electric, NetBotz 750, SNMP - Resolved an issue in which some door sensors were not appearing.
- Phoenix Power Corporation, UPS - Resolved an issue which caused incorrect status.
Device library v1.9.0.176
January 2021
- Schneider Electric, Sepam S20 Relay, Modbus
- Schneider Electric, Conext Gateway, Modbus
- Schneider Electric, Conext XW+ Inverter, Modbus
- Bachmann, BlueNet BN2000 RPDU, SNMP
- Geist, Watchdog EMS, SNMP
- Geist, Watchdog 100, EMS, SNMP
- IT Watchdogs, WxGoos-1, EMS, SNMP
- IT Watchdogs SuperGoose II, EMS, SNMP
- Rittal, CMC III LCP (type 1.3.6.1.4.1.2606.7.7.4.9217), SNMP
- Schneider Electric, TSATRA and Amico cooling devices - Added NMC component
- APC, Easy RPDU - Fixed unhandled exception and added more descriptive sensor names
Device library v1.9.0.163
December 2020
- Schneider Electric, Micro Data Center, SNMP
- Schneider Electric, Galaxy UPS, Modbus
- Schneider Electric, Gutor, BMS BACS, Modbus
- BlackBox, Environmental Monitor, SNMP
- DB Power Electronics, 120KVA UPS, SNMP
- Geist, IMD RPDU, SNMP
- Phoenix Broadband Technologies, PowerAgent BMS, SNMP
- Rittal CMC III, LCP Chassis/PDU/PU ZUCS/PU, SNMP
Updated devices
- Schneider Electric, Gutor BMS BACS, SNMP - Added Battery String sensors
- APC UPSs - Fixed data type such that "Output Energy Usage" can now be larger than 2,1474,836 kWh
- APC UPSs - Fixed scaling and name of "Low Battery Shutdown Threshold"
- Alcatel Switch, SNMP - Fixed enumeration issue
- Geist V5, PDU, SNMP - Fixed discovery issue
- Kamstrup Multical, Modbus - Fixed scaling issue
- PPC, UPS, SNMP - Added additional alarms, fixed enumerations, and changed sensor names for clarity
Device library v1.9.0.148
November 2020
New device support (Vendor, Series/Type, Protocol)
- Schneider Electric, Power Meter, ION8600, Modbus
- Eaton, Switched ePDU, SNMP
- PDI, BCMS II Plus, SNMP
- PowerShield, Battery String Monitor, SNMP
- Rittal, Chillers with Carel pco5+ cards, SNMP
- Rittal, Smart PDU, SNMP
Updated devices
- Schneider Electric, Easy RPDU - Fixed issue related to device discovery.
- APC, BMSHVA Battery Manager - Fixed issue with incorrect scaling on ohmic values.
- MGE, Galaxy - Added a work around to allow devices with incorrect serial numbers to discover.
Device library v1.9.0.134
October 2020
New device support (Vendor, Series/Type, Protocol)
- Tripp Lite, PDU with WEBCARDLX, SNMP
- Enlogic, Input Metered PDU, SNMP
- Lenovo, Smart RPDU, SNMP
Updated devices
- Schneider Electric, Gutor, Battery Manager - Added new state sensors for Gutor with status information.
- Schneider Electric, Easy RPDU - Added alarms based on the user defined thresholds from the device
- Generic UPSMIB - Updated the alarm severities
Device library v1.9.0.127
October 2020
New device support (Vendor, Series, Type, Protocol)
- Schneider Electric, Acti9 SmartLink and SmartLink SI B, Gateway for PowerTag energy sensors, Modbus
- Schneider Electric, Easy RPDU, SNMP
- Schneider Electric, Gutor, Battery Manager, SNMP
- Schneider Electric, APC, Air Economizer, CRAC, SNMP
- Schneider Electric, Easy Cooling, InRow Chiller, Modbus
- Schneider Electric, Uniflair, ARAnew, SNMP
- Schneider Electric, Uniflair, DSAF, Chiller, SNMP
- Schneider Electric, Uniflair, Rack Mount DX, CRAC, Modbus
- Schneider Electric, Uniflair LE and LE L, CRAC, SNMP
- Emerson, NXR, UPS, SNMP
- Emerson, NXC 30-40k, UPS, SNMP
- Geist, R-Series v5, PDU, SNMP
- HP, PDU, SNMP
- Kamstrup, Multical 62/601/602/801, Energy Flow Meter, Modbus
- Janitza, UMG96, Power Analyzer, SNMP
- Liebert, PeX, CRAC, Modbus
- NTI, Enviromux 2D and 5D, Environmental Monitor, SNMP
- Redetec, PN/RED/3.0, Fire Suppression System, SNMP
- Rittal, CMC Processing Unit, Controller, SNMP
- Socomec, NetVision7, UPS, SNMP
- TrippLite, WEBCARDLX, ATS, SNMP
- Vertiv, GXT4, UPS, SNMP
Comments
0 comments
Please sign in to leave a comment.