Instructions on how to reset the Gateway admin password for Gateway 1.8 and newer are here. |
Windows
You must be an Administrator or run the command prompt as administrator.
-
Open a command window. Right-click the command prompt icon and click Run as administrator.
-
Navigate to C:\Program Files\EcoStruxure IT Gateway\X.X.X\restore.
Type the command cd C:\Program Files\EcoStruxure IT Gateway\X.X.X\restore -
Type the command restore.bat password-reset
-
Go to Control Panel > Administrative Tools > Services.
-
Restart the "EcoStruxureITGateway Server - X.X.X.X" service.
Linux
-
Open a command window and type cd /opt/ExoStruxureITGateway/X.X.X/restore
-
Type ./restore.sh password-reset
-
Restart the EcoStruxure IT Gateway Server. Type systemctl restart EcoStruxureITGateway-X.X.X.service
The systemctl command can be run from any directory by sudo users.